Light Commercial / Commercial R410A
Ducted High Pressure
- Low noise level
- Compact design
- ‘Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without
- compromising the cooling capacity. More than 20% of the air conditioner's thermal cooling capacity is penalised.
- Condensate drain by gravity - drain pump not provided
Energy class in cooling: A
Energy class in heating: A
Features

Silence
The use of DC Inverter fans and the optimisation of the design decrease the noise level of the indoor units. With the Silence setting, noise levels can be kept low.

Fresh Air
The exchange of air allows the introduction of clean air into the environment. The "Fresh Air" air inlet predisposition introduces fresh air into the room, up to a maximum of 20% of the nominal air flow of the unit.
Fresh Air
'Fresh air’ knockout is incorporated in the chassis to allow fresh air introduction of up to 20% of nominal unit air flow without compromising the cooling capacity.
On/Off Card
Our unique smart connection key card management system reduces your energy costs without compromising your guests' comfort. When guests enter and leave their hotel room, the smart key cards automatically communicate with the unit to turn off the air conditioning or heating.
Wi-Fi (Optional)
Download the Haier Smart Air 2 app to an Apple or Android device and connect the equipment to your
device to control your system from anywhere at any time.
device to control your system from anywhere at any time.
Quiet
Power as well as comfort, and quiet operation matters whilst enjoying your free time. With a low noise level you can have it all.
Compact Design
Compact design for flexible installation in confined spaces.
Technical Specifications
Commercial R410A
Indoor Model No. | Outdoor Model No. | Output power - cooling | Output power - Heating | Energy Class: SEER | Energy Class: SCOP | IU size (mm) W x D x H | OU Size (mm) W x D x H |
---|---|---|---|---|---|---|---|
ADH125H1ERG | 1U48LS1ERA(S) | 12.5 (6.0 - 14.5) | 14.1 (6.0 - 16.5) | 5.3 (A) | 3.4 (A) | 1350x490x425 | 1008x410x830 |
ADH125H1ERG | 1U48LS1ERB(S) | 12.5 (6.0 - 14.5) | 14.1 (6.0 - 16.5) | 5.3 (A) | 3.4 (A) | 1350x490x425 | 1008x410x830 |
ADH140H1ERG | 1U60IS2ERB(S) | 13.6 (6.0 - 15.0) | 15.5 (6.0 - 17.5) | 5.2 (A) | 3.4 (A) | 1350x490x425 | 948x340x1250 |
ADH160H1ERG | 1UH160P1ERG | 15.5 (3.5 - 17.5) | 18.0 (6.0 - 20.0) | 6.1 | 4 | 1350x490x425 | 1350x950x370 |
ADH200H1ERG | 1UH200W1ERK | 20.5 (6.2 - 23.5) | 22.8 (7.2 - 24.8) | 6.1 | 4 | 1350x490x425 | 1636x1050x400 |
ADH250H1ERG | 1UH250W1ERK | 24.0 (7.2 - 26.5) | 26.8 (8.2 - 28.8) | 6.1 | 4 | 1350x490x425 | 1636x1050x400 |
The data shown is purely indicative and is subject to change. Buyers are advised to check the accuracy with the supplier before purchasing.
Documentation