Filters

No product filters applied.

RM1 - Electric Water Heater

RM1 - Electric Water Heater

The RM1 series Electric Water Heater offers the flexibility of both horizontal and vertical installation. It ensures a safe shower experience with Shock Proof and provides outstanding durability with super enamel tank. Available in 80L and 100L capacities, it can meet diverse hot water needs.

Additional Information

Technical Specifications | RM1 - Electric Water Heater

FE1W/FE1 - Electric Water Heater

FE1W/FE1 - Electric Water Heater

The FE1 Series Electric Water Heater offers flexible installation options, being suitable for both horizontal and vertical placement. It utilizes butt welding technology, which makes it more robust and leak-proof. Equipped with Shock Proof, it ensures safe water usage. Available in 50L, 80L, and 100L capacities, it can meet a diverse range of needs.

Additional Information

Technical Specifications | FE1W/FE1 - Electric Water Heater

FE3W/FE3 - Electric Water Heater

FE3W/FE3 - Electric Water Heater

The FE3 Electric Water Heater is equipped with the AI Anode Anticorrosion System and DualEnamel™ Heating Tech, which not only ensure long-term durability but also provide clean and healthy hot water. With available capacities of 50L, 80L, and 100L, and functions like 3kW Twin Power, it can effectively meet various household hot water demands.

Additional Information

Technical Specifications | FE3W/FE3 - Electric Water Heater

Innovation, partnership and customer engagement were at the heart of the Frigro Installer Event 2025

On 5 September, our long-standing distribution partner Frigro hosted its highly anticipated end of summer event at their warehouse in Belgium – and the day was a resounding success. With more than 500 key customers, installers, and industry professionals in attendance, the event created the perfect stage for networking, discovery, and lively exchanges within the HVAC community. 

Alternergy

Unit 10
Turnham Green Terrace Mews
Chiswick, London
W4 1QU

Pacair

Units 1 & 2
The Heron Business Park
Eastman Way, Hemel Hempstead
Hertfordshire
HP2 7FW

MRV7 S

MRV7 S

The New R32 MRV7 S system offers a powerful combination of high energy efficiency, innovative design, and a steadfast commitment to safety and environmental responsibility. This system not only enhances operational performance and simplifies installation procedures but also strengthens leak protection and significantly increases system flexibility. The MRV7 S is suitable for a diverse array of applications across vertical markets and is available in 4,5 & 6 HP single fan and 8,10 & 12HP double fan both with font discharge. 

Additional Information

Integrating Safety with Precision

The MRV7 S is engineered with a multi-zone leak detection system, providing comprehensive safety through built-in leak detectors in all our indoor units. The system incorporates visual and audible alarms within the new controllers. For added flexibility, an optional automatic shut-off valve can be installed, supported by a battery-powered emergency function, which is especially useful during power outages. This feature also allows for zone segregation, enabling the valve to isolate refrigerant and prevent leaks. These advanced safety protocols are built-in to proactively manage and reduce risks throughout the product’s lifecycle, from its initial design to its day-to-day operation, fully compliant with the new EU regulation 573/2024.

Multi-zone leak detection system

Integrating Installation and Control Flexibility

To further enhance efficiency, the MRV7 S features automatic addressing functionality. This simplifies the commissioning process by automatically assigning unique addresses to each indoor unit, eliminating the need for manual configuration. This is particularly advantageous for larger VRF systems with numerous 
indoor units, making both installation and commissioning processes more efficient and user-friendly. The new R32 MRV indoor units are all backward compatible with R410A refrigerant, reducing complexity from logistics to installation.

Automatic addressing functionality

Diamond Shield - R32 Safety Protection

  • Software: new version of the MRV selection software calculates the amount of refrigerant in the room and alerts if the safety limit is exceeded.
  • Alarm: the wired controller, panel and wall-mounted refrigerant detector can trigger a sound and light alarm in the case of a refrigerant leak.
  • Battery: SVP160A are equipped with a back-up battery, in order to supply power to close the shut off valves in the event of a system power failure.
  • Leak Detectors: Indoor units are equipped with built in leak detectors. There is no need to replace them after detection.
  • Recovery: In the case of a leakage, the system can recover the R32 refrigerant to the ODU and will be isolated by the shut off valves (single fan ODU). Unaffected units with SVP160A will continue operation, providing comfortable temperature to the user.
  • Shut off valve: the 4/5/6 HP MRV7 S outdoor units are equipped with built-in R32 shut off valves.
  • For the 8/10/12 HP MRV7 S outdoor units, an optional external shut off valve box (SVP160A) can be installed wherever it is necessary.
 

 

 

Technical Specifications | MRV7 S